General Information

Size Range: 1/2” through 30”
Material: Carbon Steel acc.to the MSS SP 58-TABLE A2/A2M
Service: Designed to support or hold the vertical pipe runs.The load is transmitted to the structure by the ears on each side.
Installation: Clamp is fitted and bolted preferably below a coupling or welded lugs on steel pipe. Clamp is designed for standard steel pipe O.D. and this must be considered in sizing the riser for other types of piping.
Ordering: Specify pipe size, figure number, name and finish.
Finish: 

  • Electro-Galvanization acc. to ASTM B 633/ASTM F 1941
  • Hot Dipped Galvanized. (HDG) acc.to ASTM A 153/123

Approvals: Complies with Manufacturer’s Standardization Society MSS SP-58 & MSS SP-69 – Type 8
Cerlificaton: UL listed.

Technical Specifications

Code No Code No for HDG Size Clamping Range S x B A L Max Recom. Load kN Weight per Box (lbs) Certification
Inch Inch O.D Inch Inch Inch
IEKRC015 IEKRC015H ½” 19/32 27/32  25/32 –  7/8 3/16x 1 3/16 M10 8 3/4 1 2 13/32 UL
IEKRC020 IEKRC020H ¾” 25/32 1 1/16  31/32 -1  1/16 3/16x 1 3/16 M10 8 29/32 1 2 7/16 UL
IEKRC025 IEKRC025H 1” 31/32 1 5/16 1  1/4  -1 11/32 3/16x 1 3/16 M10 9 7/32 1 2 9/16 UL
IEKRC032 IEKRC032H 1 ¼” 1 1/4 1 21/32 1  5/8  -1 11/16 1/4 x 1 3/16 M12 9 17/32 1 3 11/32 UL
IEKRC040 IEKRC040H 1 ½” 1 9/16 1 29/32 1 13/16 -1 15/16 1/4 x 1 3/16 M12 9 3/4 1 3 15/32 UL
IEKRC050 IEKRC050H 2” 1 31/32 2 3/8 2  9/32 -2 13/32 1/4 x 1 3/16 M12 10 1/4 1 3 21/32 UL
IEKRC065 IEKRC065H 2 ½” 2 9/16 3 2 29/32 -3  1/32 1/4 x 1 3/16 M12 10 7/8 2 3 31/32 UL
IEKRC080 IEKRC080H 3” 3 5/32 3 1/2 3 11/32 -3  1/2 1/4 x 1 3/16 M12 11 11/32 2 4 7/32 UL
IEKRC090 IEKRC090H 3 ½” 3 17/32 4 3 27/32 -4  1/32 1/4 x 1 9/16 M12 13 1/16 3 6 5/32 UL
IEKRC100 IEKRC100H 4” 3 15/16 4 1/2 4  3/8  -4 17/32 1/4 x 1 9/16 M12 13 17/32 4 6 15/32 UL
IEKRC125 IEKRC125H 5” 4 29/32 5 9/16 5  7/16 -5 19/32 1/4 x 1 31/32 M12 14 17/32 5 8 21/32 UL
IEKRC134 IEKRC134H 6 7/32 6 7/32 6  5/32 -6  5/16 1/4 x 1 31/32 M12 15 3/16 6 9 1/16
IEKRC150 IEKRC150H 6” 5 29/32 6 5/8 6  1/2  -6 21/32 1/4 x 1 31/32 M12 15 21/32 7 9 11/16 UL
IEKRC185 IEKRC185 7 9/16 7 9/16 7 13/32 -7  9/16 13/32x 1 31/32 M16 17 7/8 10 9 27/32
IEKRC200 IEKRC200H 8” 7 7/8 8 5/8 8  1/2  -8 21/32 13/32x 1 31/32 M16 18 29/32 11 19 19/32 UL
IEKRC250 IEKRC250H 10” 9 27/32 10 3/4 10  5/8  -10 25/32 13/32x 1 31/32 M16 20 31/32 11 22 9/16 UL
IEKRC300 IEKRC300H 12” 11 13/16 12 3/4 12 19/32 -12  3/4 15/32 x 2 3/8 M16 23 12 35 9/32 UL
IEKRC350 IEKRC350H 14” 13 25/32 14 13 27/32 -14  1/32 15/32 x 2 3/8 M16 24 1/4 12 37 5/8
IEKRC400 IEKRC400H 16” 15 3/4 16 15  7/8  -16  1/32 5/8 x 2 3/8 M20 26 1/4 13 55 7/16
IEKRC450 IEKRC450H 18” 17 23/32 18 17  7/8  -18  1/32 5/8 x 2 3/8 M20 28 7/32 13 60 13/32
IEKRC500 IEKRC500H 20” 19 11/16 20 19  7/8  -20  1/32 5/8 x 2 3/8 M20 30 9/32 13 67 3/32
IEKRC600 IEKRC600H 24” 23 5/8 24 23 27/32 -24  1/32 5/8 x 2 15/16 M20 34 1/4 13 95 19/32
IEKRC750 IEKRC750H 30” 29 17/32 30 29  7/8  -30  1/32 5/8 x 2 15/16 M20 40 9/32 13 116 3/32